AudioCodes Mediant 800B User Manual page 720

Media gateway & enterprise session border controller (e-sbc)
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

Note:
You must connect both ports (two) in the Ethernet Group of the Maintenance
interface to the network (i.e., two network cables are used). This provides 1+1
Maintenance port redundancy.
2.
Power up the devices; the redundant device synchronizes with the active device and
updates its configuration according to the active device. The synchronization status is
indicated as follows:
Active device: The Web interface's Home page displays the HA status as
"Synchronizing".
When synchronization completes successfully, the redundant device resets to apply
the received configuration and software.
When both devices become operational in HA, the HA status is indicated as follows:
Both devices: The Web interface's Home page displays the HA status as
"Operational".
Active device: The Status LED is lit green - slow-flash, steady on, and then slow
flash
Redundant device: The Status LED is lit green - slow-fast flash
3.
Access the active device with its OAMP IP address and configure the device as
required. For information on configuration done after HA is operational, see
''Configuration while HA is Operational'' on page 721.
User's Manual
Mediant 800B Gateway and E- SBC
720
Document #: LTRT-10296