Parameter
[CharConversion_Index]
Character Name
char-name
[CharConversion_CharName]
First Byte
first-byte
[CharConversion_FirstByte]
Second Byte
second-byte
[CharConversion_SecondByte]
Converted Output
converted-output
[CharConversion_ConvertedOutput]
User's Manual
Note: Each row must be configured with a unique index.
Defines an arbitrary name to easily identify the row.
The valid value is a string of up to 40 characters.
Note: Each row must be configured with a unique name.
Defines the first byte of the Unicode character (e.g., 195).
The default is 194.
Defines the second byte of the Unicode character (e.g., 164).
The default is 128.
Defines the ASCII character (e.g., "ae") to which the Unicode
character must be converted.
The valid value is a string of up to four characters.
The valid value is up to four ASCII characters. This can include
any ASCII character - alphanumerical (e.g., a, A, 6) and/or
symbols (e.g., !, ?, _, &).