To configure a number manipulation rule:
1.
Open the required Number Manipulation page (Configuration tab > VoIP menu >
Gateway > Manipulations > Dest Number IP->Tel, Dest Number Tel->IP, Source
Number IP->Tel, or Source Number Tel->IP); the relevant Manipulation table page is
displayed.
2.
Click Add; the following dialog box appears:
Figure 23-2: Number Manipulation Table (Example) - Add Row Dialog Box
3.
Configure a number manipulation rule according to the parameters described in the
table below.
4.
Click Add.
The table below shows configuration examples of Tel-to-IP source phone number
manipulation rules, where:
Rule 1: When the destination number has the prefix 03 (e.g., 035000), source number
prefix 201 (e.g., 20155), and from source IP Group ID 2, the source number is
changed to, for example, 97120155.
Rule 2: When the source number has prefix 1001 (e.g., 1001876), it is changed to
587623.
Rule 3: When the source number has prefix 123451001 (e.g., 1234510012001), it is
changed to 20018.
Rule 4: When the source number has prefix from 30 to 40 and a digit (e.g., 3122), it is
changed to 2312.
Rule 5: When the destination number has the prefix 6, 7, or 8 (e.g., 85262146),
source number prefix 2001, it is changed to 3146.
Parameter
Destination
Prefix
Source Prefix
Version 7.0
Rule 1
Rule 2
03
201
1001
Rule 3
*
123451001#
471
Mediant 800B Gateway and E- SBC
23. Manipulation
Rule 4
Rule 5
*
[6,7,8]
[30-40]x
2001