2.
Click Add; the following dialog box appears:
Figure 18-5: Message Policy Table - Add Row Dialog Box
3.
Configure a Message Policy rule according to the parameters described in the table
below.
4.
Click Add.
Table 18-3: Message Policy Table Parameter Descriptions
Parameter
Index
[MessagePolicy_Index]
Name
name
[MessagePolicy_Name]
Max Message Length
max-message-length
[MessagePolicy_MaxMessageLength]
Max Header Length
max-header-length
[MessagePolicy_MaxHeaderLength]
Max Body Length
max-body-length
[MessagePolicy_MaxBodyLength]
Version 7.0
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Defines an arbitrary name to easily identify the row.
The valid value is a string of up to 20 characters.
Note: Each row must be configured with a unique name.
Defines the maximum SIP message length.
The valid value is up to 32,768 characters. The default is
32,768.
Defines the maximum SIP header length.
The valid value is up to 512 characters. The default is 512.
Defines the maximum SIP message body length. This is the
value of the Content-Length header.
The valid value is up to 1,024 characters. The default is
1,024.
385