Honda MUV700 big red Service Manual page 582

Table of Contents

Advertisement

LIGHTS/METERS/SWITCHES
4.
Cooling
Fa
n Motor Operation Inspection
Connect
the Green/black and Green wire termi-
,
- - - - - - - - - - - - - - - - - - -
PCM
5P
BLACK
CONNECTOR
(Terminal
side
of
the
wi
re harness)
24-12
nals of the wire harness side 5P connector
with
the
jumper
wire.
Turn the ignition
switch
to ON and check the
cooling
fan.
Does the
cooling
fan
start?
YES
- Replace the peM with a known
good
one,
and
recheck.
NO
- GO TO STEP 5.
5.
Cooling
Fan Motor Ground line Inspection
Turn the ignition switch to OFF.
Disconnect the cooling fan 2P brown connector.
With the jumper wire connected to the peM 5P
connector,
check for continuity
between
the
Green/black
wi
re terminal
of
the
wire
harness
side 2P connector and ground.
Is there
continuity?
YES
- GO TO
STE
P 6.
NO
- Open circuit in the Green/black wire.
6.
Cooling
Fan Motor Power Input Line Inspection
Turn the
ignition
switch to ON.
Measure the voltage between the Blue wire ter-
minal
(+)
of
the wire
harness
side 2P
connector
and ground
(-).
Is
there battery voltage
?
YES
-
Replace the cooling fan motor with a
new
one
(page
7-11).
NO
- Open
circuit
in the
Blue
wire between
the
cooli
ng
fan and fuse box.
Green/black
/,
r
J
~
~~
\
JUMPER WIRE
Green
COOLING FAN 2P BROWN CONNECTOR
(Term
inal
side of the wire harness)
Green/black
Q
COOLING FAN 2P BROWN CONNECTOR
(Terminal
side
of
the wire harness)
r,
8~V
®
Blue
-

Advertisement