Remove Power Distribution Board
The power distribution board is a FRU and can only be replaced by an Oracle-qualified service
technician.
Caution -
Electrostatic Discharge and Antistatic Prevention Measures" on page
components along their connector edges.
Caution -
installing the power distribution board. Power down both server nodes (also called system
controllers) and disconnect the power cords from the system before performing these
procedures. For instructions, see
System" on page
This section includes:
"Remove Power Distribution Board" on page 172
"Install Power Distribution Board" on page 174
Remove Power Distribution Board
Note -
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
This section describes removing the power distribution board from Oracle Database Appliance
Version 1.
1.
Prepare the system for service.
Power off the system.
a.   
See
b.   
Disconnect the power cords from the system.
c.   
If the system is installed in a rack, remove it.
For information on racking the system chassis, see the Oracle Database Appliance
Owner's Guide.
d.   
Remove both power supplies from the system.
See
172
Oracle Database Appliance Service Manual • June 2017
Equipment damage. Follow antistatic precautions as described in
Equipment damage. Remove all power from the system before removing or
109.
Information in this appendix does NOT apply to Oracle Database Appliance X3-
"Shutting Down a Server Node and Powering Off the System" on page
"Remove a Power Supply" on page
"Shutting Down a Server Node and Powering Off the
129.
"Performing
112. Do not touch the
109.