Place ESD-sensitive components on an antistatic mat. The following items can be used as
■
an antistatic mat:
Antistatic bag used to wrap a replacement part
■
ESD mat
■
Disposable ESD mat (shipped with some replacement parts or optional system
■
components)
Removing Server Nodes From the System Chassis
Information in this appendix does NOT apply to Oracle Database Appliance X3-
Note -
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
You must remove the Oracle Database Appliance Version 1 server node from the chassis to
remove or replace internal server node components.
Remove a Server Node From the System Chassis
Information in this appendix does NOT apply to Oracle Database Appliance X3-
Note -
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
The removal procedure is the same for both server nodes. Note that you do not need to remove
the entire system chassis from the rack to perform service procedures on a server node.
Replacing a server node FRU with a new server node is a service activity that must be
Note -
performed by an Oracle-qualified service technician. The customer may remove the server node
to service other CRU components in the server node.
1.
Shut down the server node.
See
"Shut Down a Server Node" on page
Data loss. To avoid data loss and file system corruption, always use a graceful
Caution -
shutdown unless it is an emergency.
2.
To unseat the server node from the system chassis, pull the two latches on the
rear of the server node down [1].
Remove a Server Node From the System Chassis
109.
Appendix A • Servicing the Oracle Database Appliance Version 1
113
Need help?
Do you have a question about the Database Appliance X6-2-HA and is the answer not in the manual?
Questions and answers