Component Replacement Policy (Crus And Frus) - Oracle Database Appliance X6-2-HA Manual

Hide thumbs Also See for Database Appliance X6-2-HA:
Table of Contents

Advertisement

Preparing to Service
"Removing the Server Node Top Cover" on page 114
"Removing the Middle Section of the System Top Cover" on page 115

Component Replacement Policy (CRUs and FRUs)

Note -
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
The replaceable components in your Oracle Database Appliance Version 1 are designated
as either field-replaceable units (FRUs) or customer-replaceable units (CRUs). Some can be
replaced with the power on, some require the powering off of a server node, and some require
the powering off of the entire system chassis.
A part designated as a FRU must be replaced by Oracle-qualified service technician.
A part designated as a CRU can be replaced by a person who is not an Oracle-qualified
service technician.
The following table lists replaceable components, their service designation (CRU or FRU), and
the system power policy related to servicing the component.
Component
Storage drives and boot drives
(CRU)
Fan modules (CRU)
Power supplies (CRU)
Air duct (FRU)
DIMMs (CRU)
PCIe risers (CRU)
PCIe cards (CRU)
Boot disk backplane (FRU)
106
Oracle Database Appliance Service Manual • June 2017
Information in this appendix does NOT apply to Oracle Database Appliance X3-
Policy
Hot-pluggable – Can be removed and replaced when the system is powered
on.
Hot-pluggable – Can be removed and replaced when the system is powered
on.
Hot-pluggable – Can be removed and replaced when the system is powered
on.
Cold service, server node – Can only be removed and replaced when the
server node is powered off. The other server node and the system chassis can
remain on.
Cold service, server node – Can only be removed and replaced when the
server node is powered off. The other server node and the system chassis can
remain on.
Cold service, server node – Can only be removed and replaced when the
server node is powered off. The other server node and the system chassis can
remain on.
Cold service, server node – Can only be removed and replaced when the
server node is powered off. The other server node and the system chassis can
remain on.
Cold service, server node – Can only be removed and replaced when the
server node is powered off. The other server node and the system chassis can
remain on.

Advertisement