Equipment damage. These procedures require that you handle components that are
Caution -
sensitive to static discharge. This sensitivity can cause the component to fail. To avoid damage,
ensure that you follow antistatic practices as described in
and Antistatic Prevention Measures" on page
This section includes the following topics:
"Remove Processor (CPU)" on page 163
■
"Install Processor (CPU)" on page 166
■
Remove Processor (CPU)
Information in this appendix does NOT apply to Oracle Database Appliance X3-
Note -
2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 or Oracle Database
Appliance X6 series. Refer to the preceding chapters in this document for information on
servicing those systems.
This section describes removing a processor from Oracle Database Appliance Version 1.
1.
Prepare the server node for service.
Attach an antistatic wrist strap.
a.
See
"Performing Electrostatic Discharge and Antistatic Prevention
Measures" on page
b.
Remove the server node from the system.
Power is removed from the server node when you remove it from the system. See
"Removing Server Nodes From the System Chassis" on page
Remove the server node top cover.
c.
See
"Removing the Server Node Top Cover" on page
d.
Remove the air duct.
See
"Remove Air Duct" on page
Remove the CPU.
2.
a.
Identify which CPU to remove.
b.
To identify the location of the faulty CPU, press the Fault Remind button on
the motherboard.
112.
112.
160.
Appendix A • Servicing the Oracle Database Appliance Version 1
Remove Processor (CPU)
"Performing Electrostatic Discharge
113.
114.
163
Need help?
Do you have a question about the Database Appliance X6-2-HA and is the answer not in the manual?
Questions and answers