Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 1036

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

• I.18010 A processor stepping mismatch has been detected for one or more processor packages.
Processors of the same model have mismatched Stepping ID
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Verify that matching processors are installed in the correct processor sockets. Correct any
mismatch found.
2. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this processor error.
3. (Trained technician only)Replace the system board
• I.2018002 The device found at Bus [arg1] Device [arg2] Function [arg3] could not be configured
due to resource constraints. The Vendor ID for the device is [arg4] and the Device ID is [arg5].
OUT_OF_RESOURCES (PCI Option ROM)
Explanation:
Severity
Info
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat the adapter and any attached cables.
2. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware
update that applies to this error. NOTE: It may be necessary to disable unused option ROMs
from UEFI F1 setup or ToolsCenter Suite CLI or using adapter manufacturer utilities so that
adapter firmware can be updated.
3. Move the adapter to a different slot. If a slot is not available or error recurs, replace the adapter.
4. If the adapter was moved to a different slot and the error did not recur, verify that this is not a
system limitation. Then replace the system board. Also, if this is not the initial installation and the
error persists after adapter replacement, replace the system board.
• I.2018003 A bad option ROM checksum was detected for the device found at Bus [arg1] Device
[arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. ROM
CHECKSUM ERROR
Explanation:
Severity
Error
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat the adapter and any attached cables.
2. Move the adapter to a different system slot, if available.
1020
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents