ModBus TCP /IP Support
Word Address
Number of Frames Received and Transmitted with a Length (Octets)
0x2A00 to 0x2A3F
0x2A40 to 0x2A7F
0x2A80 to 0x2ABF 2 words
0x2AC0 to 0x2AFF 2 words
0x2B00 to 0x2B3F
0x2B40 to 0x2B7F

CLI Commands for Modbus TCP/IP

The CLI commands for Modbus TCP/IP are listed in the following table.
Modbus TCP/IP Commands
Enable
Disable
Set Modbus Interval Time
between Request
Set Modbus TCP Master
Communicate Session
Set Modbus TCP
Listening Port
208 - CLI Commands for Modbus TCP/IP
Data Type
2 words
64
2 words
65 to 127
128 to 255
256 to 511
2 words
512 to 1023
2 words
1024 to maximum size
Switch(config)# modbus enable
Switch(config)# modbus disable
Switch(config)# modbus idle-timeout
<200-10000>
Timeout value: 200-10000ms
Switch(config)# modbus idle-timeout 200
Switch(config)# modbus master
<1-20> Max Modbus TCP Master
Switch(config)# modbus master 2
Switch(config)# modbus port
<1-65536>
Port Number
Switch(config)# modbus port 502
Description
RocketLinx ES8509-XT User Guide: 2000557 Rev. D