Rate Control - Comtrol ROCKETLINX ES8509-XT User Manual

Industrial managed switch
Hide thumbs Also See for ROCKETLINX ES8509-XT:
Table of Contents

Advertisement

Configuration Using the Web Interface

Rate Control

Rate control is a form of flow control used to enforce a strict bandwidth limit of a port. You can program
separate transmitting (Egress Rule) and receiving (Ingress Rule) rate limits for each port, and even apply the
limit to certain packet types as described below.
Rate Control Page
You can select the packet type that you want to filter. The Ingress packet types
supported are:
Ingress
Packet Type
The Egress rate supports all types of packets.
All ports support port Ingress and Egress rate control. For example, assume Port 1
is 10Mbps, you can set it's effective Egress rate at 2Mbps, Ingress rate at 1Mbps.
The ES8509-XT performs the Ingress rate by packet counter to meet the specified
rate.
Bandwidth
Click Apply to apply the settings.
Apply
Note: You must Save the settings
70 - Rate Control
Broadcast/Multicast/Unknown Unicast
Broadcast/Multicast
Broadcast
All
Ingress
Ingress rate in Mbps, the rate range is from 1 Mbps to 100 Mbps and zero
means no limit. The default value is 8Mbps
Egress
The default value is no-limit. Egress rate limiting has an effect on all types of
packets, including Unicast, Multicast and Broadcast packets.
if the ES8509-XT is powered off.
(Page
127), if you want to maintain these settings
RocketLinx ES8509-XT User Guide: 2000557 Rev. D