Diagnostics
18
Monitor port operation for approximately five minutes.
Did a link incident or No Light message recur?
YES
↓
19
Clean fiber-optic connectors on the jumper cable.
1. Notify the customer the port will be blocked. Ensure the customer's system
2. Block the port. Refer to
3. Disconnect both ends of the fiber-optic cable.
4. Clean the fiber-optic connectors. Refer to
5. Reconnect the fiber-optic cable.
6. Unblock the port. Refer to
7. Monitor port operation for approximately five minutes.
Did a link incident or No Light message recur?
YES
↓
20
Disconnect the fiber-optic jumper cable from the switch port and connect the
cable to a spare port.
Does a link incident or No Light message display?
YES
↓
66
NO
The Fibre Channel link and switch appear operational. Exit MAP.
administrator quiesces Fibre Channel frame traffic through the port and sets
the attached device offline.
on page 111.
NO
The Fibre Channel link and switch appear operational. Exit MAP.
NO
Go to
step
22.
"Block or Unblock a
"Clean Fiber-Optic
"Block or Unblock a
Port" on page 109.
Components"
Port" on page 109.
Edge Switch 2/12 Service Manual