Table 72: Event Code 584
Message:
Not operational primitive sequence received.
Severity:
Major.
Explanation:
A not-operational primitive sequence (NOS) was received.
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
Table 73: Event Code 585
Message:
Primitive sequence timeout.
Severity:
Major.
Explanation:
Either a link reset (LR) protocol timeout or a timeout while waiting for the
appropriate response (while in a NOS receive state and after NOS was no longer
recognized) occurred.
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/12 Service Manual
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
"MAP 0000: Start
E-Mail
Call
Home
"MAP 0000: Start
E-Mail
Call
Home
Event Codes
MAP" on
Host
Sense
Link
Info
Incident
MAP" on
Host
Sense
Link
Info
Incident
169

Advertisement

Table of Contents
loading

Table of Contents