Table 4: Event Codes versus Maintenance Action (Continued)
Event
Code
062
063
070
071
072
073
074
080
081
120
121
140
141
142
143
Edge Switch 2/12 Service Manual
Explanation
Maximum interswitch hop count
exceeded.
Remote switch has too many ISLs.
E_Port is segmented.
Switch is isolated.
E_Port connected to unsupported
switch.
Fabric initialization error.
ISL frame delivery error threshold
exceeded.
Unauthorized worldwide name.
Invalid attachment.
Error detected while processing system
management command.
Zone set activation failed - zone set
too large.
Congestion detected on an ISL.
Congestion relieved on an ISL.
Low BB_Credit detected on an ISL.
Low BB_Credit relieved on an ISL.
Action
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
Go to
"Collect Maintenance
Data" on page
105.
Go to
"Collect Maintenance
Data" on page
105.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0500: Port Failure
and Link Incident Analysis
Go to Go to
"Collect
Maintenance Data" on
page
105.
Reduce size of zone set and
retry.
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
No action required.
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
No action required.