Table 68: Event Code 525
Message:
FL_Port arbitration timeout.
Severity:
Informational.
Explanation:
A switch port could not win loop arbitration within the specified loop protocol time
out value (LP_TOV).
Action:
Switch firmware reinitializes the arbitrated loop. No user action required.
Event Data:
Byte 0 = port number (00 through 11).
Distribution:
Switch
EWS
Event
Log
Table 69: Event Code 581
Message:
Implicit incident.
Severity:
Major.
Explanation:
The event caused an implicit Fibre Channel link incident.
Action:
A link incident record (LIR) is generated and sent to the attached server using the
reporting procedure defined in T11/99-017v0 (OSI). If fault isolation at the server
does not detect a failure, the problem may be due to a port failure. Go to
0000: Start
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/12 Service Manual
HAFM Appliance
System
Event
Error
Log
LED
MAP" on page 32 to perform fault isolation.