HP StorageWorks Edge Switch 2/12 Service Manual page 83

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

8. Set both switches online. Refer to
Did the domain ID change solve the problem and did both switches join through
the ISL to form a fabric?
NO
Contact the next level of support. Exit MAP.
15
A switch E_Port segmented because two switches had incompatible zoning
configurations. An identical zone name is recognized in the active zone set for
both switches, but the zones contain different members.
1. Work with the system administrator to determine the desired zone name
2. At the View panel, select Configure at the left side of the panel. The
3. Click the Zoning tab, then click the Zones tab. The Zones page displays.
4. Inspect zone names (listed under Display Previous Zones) in the active zone
5. Modify the incompatible zone name as directed by the customer. Refer to the
Did the zone name change solve the problem and did both switches join through
the ISL to form a fabric?
NO
Contact the next level of support. Exit MAP.
Edge Switch 2/12 Service Manual
page 107.
YES
The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
change for one of the affected switches. Zone names must conform to the
following rules:
— The name must be 64 characters or fewer in length.
— The first character must be a letter (a through z), upper or lower case.
— Other characters must be alphanumeric (a through z
or 0 through 9), dollar sign ($), hyphen (-), caret (^), or underscore (_).
Configure panel opens with the Ports page displayed.
set to determine the incompatible name.
HP StorageWorks Edge Switch 2/12 Installation Guide for more information
on configuring zones.
YES
The switch, associated ISL, and multiswitch fabric appear
operational. Exit MAP.
"Set the Switch Online or
Diagnostics
Offline" on
83

Advertisement

Table of Contents
loading