Table 40: Event Code 151
Message:
Fabric configuration failure.
Severity:
Informational.
Explanation:
A fabric-wide configuration activation process failed. An event code 151 is
recorded only by the managing switch in the fabric. The event code is intended to
help engineering support personnel fault isolate fabric-wide configuration failures.
Action:
Perform the procedure described in
Event Data:
Event data are mapped from the software implementation of the FC-SW2 protocol
and are typically complicated. Decoding the event data requires engineering
support. Event data are as follows:
Bytes 0 - 3 = Managing switch domain ID in internal format (1-31).
Bytes 4 - 7 = Fabric configuration operation that failed.
Bytes 8 - 11 = Fabric configuration step that failed.
Bytes 12 - 15 = Managed switch domain ID in internal format (1-31).
Bytes 16 - 19 = Response command code received from the managed switch.
Bytes 20 - 23 = Response code received from the managed switch.
Bytes 24 - 27 = Reason code received from the managed switch.
Bytes 28 - 31 = Error code received from the managed switch.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/12 Service Manual
HAFM Appliance
System
Event Log
Error LED
"Collect Maintenance Data" on page 105
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
151