HP StorageWorks Edge Switch 2/12 Service Manual page 156

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

Event Codes
Table 49: Event Code 411
Message:
Firmware fault.
Severity:
Major.
Explanation:
Switch firmware encountered an unexpected condition and dumped operating state
information to FLASH memory for retrieval and analysis. The dump file
automatically transfers from the switch to the server, where it is stored for later
retrieval through the data collection procedure.
The switch performs a software reset, during which all attached Fibre Channel
devices are momentarily disrupted, log out, and log back in.
Action:
Perform the procedure described in
Event Data:
Bytes 0 through 3 = fault identifier, least significant byte first.
Distribution:
Switch
EWS
Event
Log
Table 50: Event Code 412
Message:
CTP watchdog timer reset.
Severity:
Informational.
Explanation:
The hardware watchdog timer expired and caused the CTP card to reset.
Action:
Perform the procedure described in
Event Data:
Byte 0 = reset type as follows:
00 = task switch did not occur within approximately one second,
01 = interrupt servicing blocked for more than approximately one second.
Distribution:
Switch
EWS
Event Log
156
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event Log
Error LED
"Collect Maintenance Data" on page
E-Mail
Call
Home
"Collect Maintenance Data" on page
E-Mail
Call-Home
Edge Switch 2/12 Service Manual
105.
Host
Sense
Link
Info
Incident
105.
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

Table of Contents