HP StorageWorks Edge Switch 2/12 Service Manual page 139

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

Table 25: Event Code 063
Message:
Remote switch has too many ISLs.
Severity:
Major.
Explanation:
The fabric element (director or switch) whose domain ID is indicated in the event
data has too many ISLs attached, and that element is unreachable from this switch.
Action:
Reduce the ISLs on the indicated fabric element to a number within the limits
specified. Refer to the
more information.
Event Data:
Byte 0 = domain ID of the fabric element (Director or Edge Switch) with too many
ISLs.
Distribution:
Switch
EWS
Event
Log
Table 26: Event Code 070
Message:
E_Port is segmented.
Severity:
Informational.
Explanation:
A switch E_Port recognized an incompatibility with an attached fabric element
(Director or Edge Switch), preventing the switch from participating in the fabric. A
segmented port does not transmit Class 2 or Class 3 traffic (data from attached
devices), but transmits Class F traffic (management and control data from the
attached Director or Edge Switch). Refer to event data for the segmentation reason.
Action:
Action depends on the segmentation reason specified in the event data.
Edge Switch 2/12 Service Manual
HP StorageWorks SAN High-Availability Planning Guide
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home