HP StorageWorks Edge Switch 2/12 Service Manual page 137

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

Table 22: Event Code 052
Message:
Management Server internal error, asynchronous status report activation, or mode
register update occurred.
Severity:
Informational.
Explanation:
An internal operating error was detected by the Management Server subsystem, an
asynchronous status was reported to an attached host, or a mode register update
occurred.
Action:
Management Server internal error: Perform the procedure described in
Maintenance Data" on page
Asynchronous status report activation: No action required.
Mode register update: No action required.
Event Data:
Supplementary data consists of reporting tasks of type eMST_SB2, with
component_id eMSCID_SB2_CHPGM. For each type of error or indication, the
subcomponent_id is:
Management Server internal error: subcomponent_id is
eMS_ELR_SB2_DEVICE_PROTOCOL_ERROR or
eMS_ELR_SB2_MSG_PROCESSING_ERROR.
Asynchronous status report activation: subcomponent_id is
eSB2_CP_RER_ASYNCH_STATUS_REPORTING.
Mode register update: subcomponent_id is eMS_ELR_MODE_REGISTER_UPDATE.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/12 Service Manual
105.
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
Event Codes
"Collect
Host
Sense
Link
Info
Incident
137

Advertisement

Table of Contents
loading

Table of Contents