Diagnostics
13
As indicated by event code 507, a Fibre Channel port failed an internal or external
loopback test.
1. At the EWS interface, reset each port that failed the loopback test.
2. Perform an external loopback test for all ports that were reset. Refer to
Did resetting ports solve the problem?
NO
14
Port beaconing may be enabled.
1. Consult the customer and next level of support to determine the reason port
2. Disable port beaconing at the EWS interface:
64
a. At the View panel, select Operations at the left side of the panel. The
Operations panel opens with the Switch and Beacon pages displayed.
b. Click the Port tab. The Operations panel opens with the Port and
Beacon pages displayed.
c. Click the Reset tab. The Reset page displays.
d. Click the check box (checked) in the Port Reset column and click
Activate to reset the port. The message Your changes have been
successfully activated appears.
"Perform Port Diagnostic Loopback
YES
The switch appears operational. Exit MAP.
beaconing is enabled.
a. At the View panel, select Operations at the left side of the panel. The
Operations panel opens with the Switch and Beacon pages displayed.
b. Click the Port tab. The Operations panel opens with the Port and
Beacon pages displayed.
c. Click the check box (checked) in the Beaconing State column and click
Activate to remove the check mark and disable beaconing. The message
Your changes have been successfully activated
appears.
Tests" on page 101.