HP StorageWorks Edge Switch 2/12 Service Manual page 170

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

Event Codes
Table 74: Event Code 586
Message:
Invalid primitive sequence received for current link state.
Severity:
Major.
Explanation:
Either a link reset (LR) or a link-reset response (LRR) sequence while in the
wait-for-online sequence (OLS) state occurred.
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
170
HAFM Appliance
System
Event
Error
Log
LED
"MAP 0000: Start
E-Mail
Call
Home
Edge Switch 2/12 Service Manual
MAP" on
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

Table of Contents