Diagnostics
Table 4: Event Codes versus Maintenance Action (Continued)
Event
Code
150
151
300
301
302
310
311
312
400
410
411
412
421
423
426
433
440
442
445
453
30
Explanation
Zone merge failure.
Fabric configuration failure.
Cooling fan propeller failed.
Cooling fan propeller failed.
Cooling fan propeller failed.
Cooling fan propeller recovered.
Cooling fan propeller recovered.
Cooling fan propeller recovered.
Power-up diagnostic failure.
Switch reset.
Firmware fault.
CTP watchdog timer reset.
Firmware download complete.
CTP firmware download initiated.
Multiple ECC single-bit errors
occurred.
Non-recoverable Ethernet fault.
Embedded port hardware failed.
Embedded port anomaly detected.
ASIC detected a system anomaly.
New feature key installed.
Action
Go to
MAP 0600: Fabric, ISL,
and Segmented Port Problem
Determination.
Go to
"Collect Maintenance
Data" on page
105.
Go to
MAP 0400: FRU Failure
Analysis.
Go to
MAP 0400: FRU Failure
Analysis.
Go to
MAP 0400: FRU Failure
Analysis.
No action required.
No action required.
No action required.
Go to
MAP 0200: POST Failure
Analysis.
No action required.
Go to
MAP 0200: POST Failure
Analysis.
Go to
"Collect Maintenance
Data" on page
105.
No action required.
No action required.
Go to
MAP 0400: FRU Failure
Analysis.
Go to
MAP 0400: FRU Failure
Analysis.
Go to
MAP 0400: FRU Failure
Analysis.
No action required.
No action required.
No action required.