Diagnostics
33
A port connection is not allowed because of a Computer Network Technologies
(CNT) wide area network (WAN) extension mode mismatch. Based on
switch-to-switch differences between the ELP maximum frame sizes allowed, a
connection was not allowed to a switch set to CNT WAN extension mode.
CNT firmware is not currently supported by HP. Exit MAP.
34
The switch and attached device are performing a Fibre Channel link reset. This is
a transient state. Wait approximately 30 seconds and inspect port state and LED
behavior.
Did the link recover and resume operation?
NO
Go to
35
A switch port state is inactive because the Flexport Technology feature key is not
installed for the port (Fibre Channel ports 4 through 11 only) or because of a
transmission speed conflict between the port configuration and the SFP optical
transceiver.
Is the inactive port a:
NO
36
Does the customer desire installation of the Flexport Technology key (ports 4
through 7 and/or ports 8 through 11)?
YES
74
YES
The Fibre Channel link and switch appear operational. Exit MAP.
step
1.
Base configuration port (Fibre Channel ports 0 through 3), or an
Installed Flexport Technology port (Fibre Channel ports 4 through 11)?
YES
Go to
step
38.
NO
The switch appears operational and the Inactive port state is
acceptable to the customer. No action is required. Exit MAP.