Diagnostics
7. Ensure the Connect using field displays COM1 or COM2 (depending on the
Figure 12: COM
8. Configure the Port Settings parameters as follows:
9. At the > prompt, type the user-level password (default is password) and press
10. At the C> prompt, type ipconfig and press Enter. The Edge-12 -
52
serial communication port connection to the switch), and click OK. The
COMn dialog box displays, where n is 1 or 2
n
Properties dialog box
— Bits per second - 115200.
— Data bits - 8.
— Parity - None.
— Stop bits - 1.
— Flow control - Hardware or None.
When the parameters are set, click Apply and OK. The Edge-12 -
HyperTerminal dialog box displays.
Enter. The password is case sensitive. The Edge-12 - HyperTerminal dialog
box displays with a C> prompt at the bottom of the window.
HyperTerminal dialog box displays with configuration information listed,
including the IP address
(Figure
13).
(Figure
12).
Edge Switch 2/12 Service Manual