Install an SFP optical transceiver in the port receptacle. Refer to
Replace an SFP Optical
Exit MAP.
12
As indicated by a message or event code 080, the eight-byte (16-digit) worldwide
name (WWN) entered to configure port binding is not valid or a nickname was
used that is not configured for the attached device. Inspect port binding
parameters at the EWS interface.
1. At the View panel, select Configure at the left side of the panel. The
2. Click the Security tab, then click the Port Binding tab. The Port Binding
3. Inspect entries in the Port WWN column. These are WWNs assigned to the
4. The bound WWN must be entered in the form of a raw WWN format
Did configuring the WWN or nickname solve the problem?
NO
Contact the next level of support. Exit MAP.
Edge Switch 2/12 Service Manual
Transceiver" on page 126.
This procedure can be performed while the switch is powered on and
operational.
Verify location of the uninstalled port.
Perform an external loopback test for the port as part of FRU removal and
replacement. Refer to.
Configure panel opens with the Ports page displayed.
page displays.
port or Fibre Channel interface installed on the attached device.
— If a nickname is not assigned to the WWN, the WWN is prefixed by the
device manufacturer's name.
— If a nickname is assigned to the WWN, the nickname appears in place of
the WWN.
(XX:XX:XX:XX:XX:XX:XX:XX) or must be a valid nickname. Ensure a
valid WWN or nickname is entered.
YES
The switch appears operational. Exit MAP.
Diagnostics
"Remove and
63