Event Codes
Table 26: Event Code 070 (Continued)
Event Data:
The first byte of event data (byte 0) specifies the E_Port number. The fifth byte (byte 4)
specifies the segmentation reason as follows:
1 = Incompatible operating parameters. Either the resource allocation time out value
(R_A_TOV) or error detect time out value (E_D_TOV) is inconsistent between the
switch and another fabric element (Director or Edge Switch). Modify the R_A_TOV
and E_D_TOV to make the values consistent for all fabric Directors and Edge
Switches.
2 = Duplicate domain ID. The switch has the same preferred domain ID as another
fabric element (Director or Edge Switch). Modify the switch Domain ID to make it
unique.
3 = Incompatible zoning configurations. The same name is applied to a zone for the
switch and another fabric element (Director or Edge Switch), but the zones contain
different zone members. Modify the zone name to make it unique, or ensure zones
with the same name contain identical zone members.
4 = Build fabric protocol error. A protocol error was detected during incorporation
of the switch into the fabric. Disconnect the E_Port link, reconnect the link, and initial
program load (IPL) the switch. If the condition persists, perform the procedure
described in
5 = No principal switch. No Director or Edge Switch in the fabric can become the
principal switch. Modify the switch priority to any value other than 255.
6 = No response from attached switch (hello timeout). The switch periodically
verifies operation of attached fabric elements (Director or Edge Switch). The switch
E_Port (at the operational switch) times out and segments if the attached device does
not respond. Check the status of the attached Director or Edge Switch. If the condition
persists, perform the procedure (at the attached device) described in
Maintenance Data" on page
Distribution:
Switch
EWS
Event Log
140
"Collect Maintenance Data" on page
105.
HAFM Appliance
System
Event Log
Error LED
105.
E-Mail
Call
Home
Edge Switch 2/12 Service Manual
"Collect
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

Table of Contents