Map 0500: Port Failure And Link Incident Analysis; Map 500 Event Codes - HP StorageWorks Edge Switch 2/12 Service Manual

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

MAP 0500: Port Failure and Link Incident Analysis

This MAP describes fault isolation for shortwave laser small form factor
pluggable (SFP) optical transceivers, longwave laser SFP optical transceivers, and
Fibre Channel link incidents. Failure indicators include:
1
Was an event code 080, 081, 506, 507, 512, 514, 581, 582, 583, 584, 585, or 586
observed at the EWS Event Log?
NO
2
Table 8
isolate faults.
Table 8: MAP 500 Event Codes
Event
Code
080
081
506
507
512
514
581
582
583
Edge Switch 2/12 Service Manual
An event code recorded at the EWS Event Log.
One or more amber LEDs on the ports illuminate.
A port operational state message or a Failed message associated with a port
at the EWS interface.
YES
Go to
step
2.
lists event codes, brief explanations of the codes, and suggested actions to
Unauthorized worldwide name.
Invalid attachment.
Fibre Channel port failure.
Loopback diagnostics port failure.
SFP optical transceiver nonfatal error.
SFP optical transceiver failure.
Implicit incident.
Bit error threshold exceeded.
Loss of signal or loss of synchronization.
Explanation
Diagnostics
Action
Go to
step
12.
Go to
step
23.
Go to
step
23.
Go to
step
13.
Go to
step
13.
Go to
step
13.
Go to
step
15.
Go to
step
15.
Go to
step
15.
59

Advertisement

Table of Contents
loading

Table of Contents