Event Codes
Table 20: Event Code 031
Message:
SNMP request received from unauthorized community.
Severity:
Informational.
Explanation:
An SNMP request containing an unauthorized community name was received and
rejected with an error. Only requests containing authorized SNMP community
names, as configured through the EWS interface, are allowed.
Action:
Add the community name to the SNMP configuration using the EWS interface.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
Table 21: Event Code 051
Message:
Management Server database invalid.
Severity:
Minor.
Explanation:
Following an IML or firmware download, the Management Server database failed
its CRC validation. All Management Services databases are initialized to an empty
state, resulting in an implicit logout of all devices logged in to the Management
Server.
Action:
Perform the procedure described in
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log