Event Codes
Table 70: Event Code 582
Message:
Bit error threshold exceeded.
Severity:
Major.
Explanation:
The number of code violation errors recognized exceeded the bit error threshold.
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
Table 71: Event Code 583
Message:
Loss of signal or loss of synchronization.
Severity:
Major.
Explanation:
A loss-of-signal condition or a loss-of-synchronization condition persisted for more
than the specified receiver-transmitter timeout value (R_T_TOV).
Action:
An LIR is generated and sent to the attached server using the reporting procedure
defined in T11/99-017v0 (OSI). If fault isolation at the server does not detect a
failure, the problem may be due to a port failure. Go to
page 32 to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
168
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
"MAP 0000: Start
E-Mail
Call
Home
"MAP 0000: Start
E-Mail
Call
Home
Edge Switch 2/12 Service Manual
MAP" on
Host
Sense
Link
Info
Incident
MAP" on
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

Table of Contents