Table 4: Event Codes versus Maintenance Action (Continued)
Event
Code
506
507
508
510
512
513
514
523
524
525
581
582
583
584
585
586
810
811
Edge Switch 2/12 Service Manual
Explanation
Fibre Channel port failure.
Loopback diagnostics port failure.
Fibre Channel port anomaly detected.
SFP optical transceiver hot-insertion
initiated.
SFP optical transceiver nonfatal error.
SFP optical transceiver hot-removal
completed.
SFP optical transceiver failure.
FL_Port open request failed.
No AL_PA acquired.
FL_Port arbitration timeout.
Implicit incident.
Bit error threshold exceeded.
Loss of signal or loss of
synchronization.
Not operational primitive sequence
received.
Primitive sequence timeout.
Invalid primitive sequence received for
current link state.
High temperature warning (CTP
thermal sensor).
Critically hot temperature warning
(CTP thermal sensor).
Action
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
No action required.
No action required.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
No action required.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
No action required.
No action required.
No action required.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0500: Port Failure
and Link Incident
Analysis.
Go to
MAP 0400: FRU Failure
Analysis.
Go to
MAP 0400: FRU Failure
Analysis.
Diagnostics
31