Diagnostics
Table 10: Invalid Attachment Reasons and Actions (Continued)
Authorization failure reject.
Unauthorized switch binding WWN.
Fabric mode mismatch.
CNT WAN extension mode mismatch.
24
The port connection conflicts with the configured port type and an ISL connection
is not allowed. Either an expansion port (E_Port) is incorrectly cabled to a Fibre
Channel device or a fabric port (F_Port) is incorrectly cabled to a fabric element.
1. At the EWS interface View panel, select Configure at the left side of the
2. At the Type column, click the arrow adjacent to the list box for the port and
3. Click Activate to save the change. The message Your changes to the
Did reconfiguring the port type solve the problem?
NO
Contact the next level of support. Exit MAP.
25
One of the following mode-mismatch conditions was detected and an ISL
connection is not allowed:
68
Reason
panel. The Configure panel opens with the Ports page displayed.
select a port type as follows:
— Select fabric port (F_Port) if the port is cabled to a device (node).
— Select expansion port (E_Port) if the port is cabled to a fabric element
(director or switch) to form an ISL.
Port Configuration have been successfully activated
appears.
YES
The switch appears operational. Exit MAP.
The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a fabric element not configured to Open Fabric 1.0 mode.
The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a legacy switch at the incorrect Exchange Link Parameter (ELP)
revision level.
Action
Go to
step
28.
Go to
step
32.
Go to
step
25.
Go to
step
33.