Field
Category
Day
Schedule (Start / Stop
Time)
Action
Description
Select which category of addresses/URLs the filter is to be used
on.
The options are first the standard categories of the Proventia
Web Filter (default value:
also be defined for the following special cases, e.g.:
: This category applies to all Internet
addresses.
: Some addresses are already known to
the Proventia Web Filter, but not yet classified. The action as-
sociated with this category is used for such addresses.
: If an address is not known to the Proventia
Web Filter, the action associated with this category is used.
Select the days on which the filter is to be active.
Possible settings:
(default value): The filter is used every day of the
week.
: The filter is used on a certain day of the week.
Only one day can be selected per filter; several filters must be
configured if several individual days are to be covered.
: The filter is used from Monday to Friday.
The default value is
In From, enter from which time the filter is to be activated. The
time is entered in the form hh:mm. Enter the time at which the
filter is to be deactivated after the to in the field. The time is
entered in the form hh:mm. The default value is 00:00 to 23:59.
Select the action to be executed if the filter matches a call.
Possible values:
(default value): The call of the requested
page is prevented and logged.
: Callup is permitted, but logged. You can
view the logged events in the Local Services->Web
Filter->Filter List menu.