Field
Third Timeserver
Time Update Interval
Time Update Policy
Internal Time Server
Description
quest.
Enter the tertiary time server, using either a domain name or an
IP address.
In addition, select the protocol for the time server request.
Possible values:
(default value): This server uses the simple network
time protocol with UDP port 123.
with UDP port 37.
with TCP port 37.
: This time server is not currently used for the time
request.
Enter the time interval in minutes at which the time is automatic-
ally updated.
The default value is
Enter the time period after which the system attempts to contact
the time server again following a failed time update.
Possible values:
(default value): The system attempts to contact the
time server after 1, 2, 4, 8, and 16 minutes.
: For ten minutes, the system attempts to con-
tact the time server after 1, 2, 4, 8 seconds, then every 10
seconds.
: For an unlimited period, the system attempts to
contact the time server after 1, 2, 4, 8 seconds, then every 10
seconds.
If certificates are used to encrypt data traffic in a VPN, it is ex-
tremely important that the correct time is set on the device. To
ensure this is the case, for Time Update Policy, select the
value
.
Select whether the internal timeserver is to be used.
10 System Management
: This server uses the time service
: This server uses the time service
.