Field
The Advanced Settings menu consists of the following fields:
Fields in the Advanced Settings menu
Field
Policy
UDP Port
Server Timeout
Value
Possible values:
(default value): Enter a new group description in the text
field.
: Select this entry for special applications,
such as Hotspot Server configuration.
: Select a predefined group from the list.
Value
Select how your device is to react if a negative response to a re-
quest is received.
Possible values:
(default value): A negative response to a
request is accepted.
not accepted. A request is sent to the next RADIUS server un-
til your device receives a response from a server configured
as authoritative.
Enter the UDP port to be used for RADIUS data.
RFC 2138 defines the default ports 1812 for authentication
(1645 in older RFCs) and 1813 for accounting (4,180.84 cm
older RFCs). You can obtain the port to be used from the docu-
mentation for your RADIUS server.
The default value is
Enter the maximum wait time between ACCESS_REQUEST
and response in milliseconds.
After timeout, the request is repeated according to Retries or
the next configured RADIUS server is requested.
Possible values are whole numbers between
The default value is
10 System Management
: A negative response to a request is
.
and
(1 second).
.