Field
Block after connection
failure for
Maximum Number of
Dialup Retries
Authentication
DNS Negotiation
Prioritize TCP ACK
Packets
Description
Enter the wait time in seconds before the device should try
again after an attempt to set up a connection has failed. The de-
fault value is
.
Enter the number of unsuccessful attempts to setup a connec-
tion before the interface is blocked.
Possible values are
to
The default value is .
Select the authentication protocol for this Internet connection.
Select the authentication specified by your provider.
Possible values:
(default value): Only run PAP (PPP Password Authentic-
ation Protocol); the password is transferred unencrypted.
Only run CHAP (PPP Challenge Handshake Authentic-
ation Protocol as per RFC 1994); password is transferred en-
crypted.
: Primarily run CHAP, otherwise PAP.
: Only run MS-CHAP version 1 (PPP Microsoft
Challenge Handshake Authentication Protocol).
: Primarily run CHAP, on denial then the
authentication protocol required by the connection partner.
(MSCHAP version 1 or 2 possible.)
: Run MS-CHAP version 2 only.
: Some providers use no authentication. In this case, se-
lect this option.
Select whether your device receives IP addresses for Primary
DNS Server and Secondary DNS Server from the connection
partner or sends them to the connection partner.
The function is enabled with
The function is enabled by default.
Select whether the TCP download is to be optimised in the
event of intensive TCP upload. This function can be specially
applied for asymmetrical bandwidths (ADSL).
.
.