Upgrading Firmware - HP AA-RS2WC-TE Installation Manual

Storageworks core switch 2/64
Table of Contents

Advertisement

Running Routine Operations

Upgrading Firmware

Use the following procedure to upgrade Core Switch 2/64 firmware.
1. This command upgrades both CPs in the switch. If you what to upgrade a
You can run firmwareDownloadStatus from a telnet session to get the
status of this command.
Note:
cards (CP0 in slot 5 and CP1 in slot 6).
166
single CP only, please use -s option. This command causes the active CP to
reset. This causes disruption to devices attached to both switch 0 and switch 1
momentarily and requires that existing telnet sessions be restarted.
firmwaredownload
option=0
Do you want to continue [Y]: y
Server Name or IP Address:
User Name:
File Name:
Password:
FirmwareDownload has started on Standby CP. It may take up to 10
minutes.
FirmwareDownload has completed successfully on Standby CP.
Standby CP reboots.
Standby CP boots up.
Standby CP booted up with new firmware.
It is highly recommended that the same firmware version is running on both CP
Core Switch 2/64 V4.1 Installation Guide

Advertisement

Table of Contents
loading