4. If you are not using multipathing software, unmount the volumes from their
5. If you are using multipathing software, use that software to remove one
6. Remove the device entries for the fabric you are migrating. For example, if
7. Login into each switch in the fabric.
8. Issue the switchDisable command.
9. Issue the configure command and change the Core Switch PID Format to
10. Issue the configenable (effective_zone_configuration) command. For
11. Issue the switchEnable command. Enable the core switches first, then the
12. Rebuild the device entries for the affected fabric using the cfgmgr
13. If you are not using multipathing software, mount all devices again and restart
14. If you are using multipathing software, reenable the affected path.
15. Repeat for all fabrics.
Core Switch 2/64 V4.1 Installation Guide
mount points using the umount command and the following syntax:
umount <mount_point>
For example:
umount /mnt/jbod
fabric's devices from its configuration.
the HBA for that fabric is fcs0, enter:
rmdev -Rdl fcs0
1.
example:
configenable my_config
edges.
command. For example:
cfgmgr -v
This command may take several minutes to complete.
If you are not using multipathing software, enter the varyonvg command to
vary on the disk volume groups, using the following syntax:
varyonvg <volume_group_name>
For example:
varyonvg datavg
I/O.For example:
mount /mnt/jbod
Technical Specifications
197