Environmental Requirements - HP AA-RS2WC-TE Installation Manual

Storageworks core switch 2/64
Table of Contents

Advertisement

Environmental Requirements

Table 17
requirements for nonoperating conditions are also provided.
Table 17: Environmental Requirements
Condition
Ambient
Temperature
Humidity
Altitude
Shock
Vibration
Heat
Dissipation
Note:
temperature at the air intake vents on the non-port side of the switch. Individual
components may have a higher range. For example, the 16-port cards and CP cards
have a temperature range up to 75
temperature of each individual component.
Core Switch 2/64 V4.1 Installation Guide
lists the environmental operating ranges for the Core Switch 2/64. The
Acceptable Range
During Operation
°
°
0
to 40
Celsius outside
switch
°
(50
to 104
20% to 85% RH
non-condensing, at
40× Celsius, with maximum
gradient of 10% per hour
0 to 3 kilometers above sea
level
(0 to 10,000 feet altitude)
4G, 11MS duration,
half-sine wave
5G, 0-3 kHz at 1.0
octave/minute
64 ports: 3690 BTU/hr
128 ports: 6700 BTU/hr
° −
°
The 0
40
C temperature range listed in
-25° to +70° Celsius outside
switch
° Farenheit
)
(-13° to 158° Farenheit)
10% to 85% RH non-condensing, at
70° Celsius
0 to 12 kilometers above sea level
(0 to 39,370 feet)
20G, 11MS duration, sq. wave
10G, 0-5 kHz at 1.0 octave/minute
Not applicable
°
C. Use the tempShow command to show the true
Technical Specifications
Acceptable Range During
Non-Operation
Table 17
represents the ambient