Sample Output For Hashow Command Before Redundancy Is Achieved; Sample Output For The Slotshow Command - HP AA-RS2WC-TE Installation Manual

Storageworks core switch 2/64
Table of Contents

Advertisement

Figure 35: Sample output for hashow command before redundancy is achieved
Note:
contact the switch supplier.
2. Enter the slotshow command. The command output should show the new
Figure 36: Sample output for the slotshow command
3. Determine the version (see
Core Switch 2/64 V4.1 Installation Guide
If not, POST is not complete or the CP cards have not yet achieved
redundancy (as shown in
command, until you can verify that redundancy has been achieved.
SW1:admin> haShow
Local CP (Slot 5, CP0): Active
Remote CP (Slot 6, CP1): Standby, Healthy
HA enabled, Heartbeat Up, HA State not in sync
SW1:admin>
If hashow command indicates any errors after redundancy is achieved,
CP card as enabled (see
SW1:admin> slotShow
Slot Blade Type ID Status
---------------------------------
1 SW BLADE 2 ENABLED
2 SW BLADE 2 ENABLED
3 SW BLADE 2 ENABLED
4 SW BLADE 2 ENABLED
5 CP BLADE 1 ENABLED
6 CP BLADE 1 ENABLED
7 SW BLADE 2 ENABLED
8 SW BLADE 2 ENABLED
9 SW BLADE 2 ENABLED
10 SW BLADE 2 ENABLED
SW1:admin>
For any firmware version, you can enter the version command
Figure
35). Wait a minute or two and reenter the
Figure
36).
Figure
37):
Installing Core Switch 2/64 FRUs
143