Table of Contents

Advertisement

Quick Links

All manuals and user guides at all-guides.com
hp StorageWorks
edge switch 2/32 installation guide
Part Number: AA-RSTZB-TE/958-000290-000
Second Edition (January 2003)
This installation guide provides procedures for setting up,
configuring, and managing the Edge Switch 2/32.

Advertisement

Table of Contents
loading

Summary of Contents for HP StorageWorks edge switch 2/32

  • Page 1 All manuals and user guides at all-guides.com hp StorageWorks edge switch 2/32 installation guide Part Number: AA-RSTZB-TE/958-000290-000 Second Edition (January 2003) This installation guide provides procedures for setting up, configuring, and managing the Edge Switch 2/32.
  • Page 2 The warranties for Hewlett-Packard Company products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. Printed in the U.S.A. hp StorageWorks edge switch 2/32 installation guide Second Edition (January 2003) Part Number: AA-RSTZB-TE/958-000290-000...
  • Page 3: Table Of Contents

    HP Technical Support ........
  • Page 4 Task 9: Configure Feature Key (Optional) ......2–15 Configure HP Flexport Technology Feature Key ..... . 2–16 Configure OSMS Feature Key .
  • Page 5 All manuals and user guides at all-guides.com Contents Configure Port Addresses (S/390 Mode) ......2–36 Configure SNMP Trap Message Recipients .
  • Page 6 All manuals and user guides at all-guides.com Contents Declaration of Conformity for Products Marked with FCC Logo—United States Only A–3 Modifications ........... . . A–3 Network and Serial Cables.
  • Page 7 All manuals and user guides at all-guides.com Contents 2–2 Connect To dialog box ......... . . 2–8 2–3 Port Settings dialog box .
  • Page 8 All manuals and user guides at all-guides.com Contents 2–40 Switch page—Identification tab ........2–56 2–41 Switch page—Date/Time tab.
  • Page 9: About This Guide

    Related Documentation For a list of corresponding documentation included with this product, see the “Related Documents” section of the hp StorageWorks edge switch release notes. For the latest information, documentation, and firmware releases, please visit the HP StorageWorks website: http://h18006.www1.hp.com/storage/saninfrastructure.html...
  • Page 10: Document Conventions

    File names, application names, and text Italics emphasis User input, command names, system Monospace font responses (output and messages) COMMAND NAMES are uppercase unless they are case sensitive Variables Monospace, italic font Website addresses Sans serif font (http://thenew.hp.com) edge switch 2/32 installation guide...
  • Page 11: Symbols In Text

    All manuals and user guides at all-guides.com About This Guide Symbols in Text These symbols may be found in the text of this manual. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life.
  • Page 12: Rack Stability

    All manuals and user guides at all-guides.com About This Guide Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component. Contact with this surface could result in injury. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.
  • Page 13: Getting Help

    Operating system type and revision level • Detailed, specific questions HP Website The HP website has the latest information on this product, as well as the latest drivers. http://thenew.hp.com/country/us/eng/prodserv/storage.html. Access storage at: From this website, select the appropriate product or solution.
  • Page 14 All manuals and user guides at all-guides.com About This Guide edge switch 2/32 installation guide...
  • Page 15: Introduction

    All manuals and user guides at all-guides.com Introduction The HP StorageWorks Edge Switch 2/32 provides dynamic switched connections between Fibre Channel servers and devices in a storage area network (SAN) environment. SANs introduce the concept of server-to-device networking and multi-switch fabrics, eliminate requirements for dedicated connections, and enable the enterprise to become data centric.
  • Page 16: Edge Switch 2/32 Description

    The switch provides connectivity for devices manufactured by multiple original equipment manufacturers (OEMs). To determine if an OEM product can communicate through connections provided by the switch, or if communication restrictions apply, refer to the supporting publications for the product or contact your HP marketing representative. 1–2...
  • Page 17: Features

    All manuals and user guides at all-guides.com Introduction Features The following sections describe the features of the Edge Switch 2/32: Error-Detection, Reporting, and Serviceability The switch provides the following error-detection, reporting, and serviceability features: • Light-emitting diodes (LEDs) on switch FRUs and adjacent to Fibre Channel ports that provide visual indicators of hardware status or malfunctions.
  • Page 18: Zoning

    SNMP trap messages. The trap messages indicate switch operational state changes and failure conditions. NOTE: For more information about SNMP support provided by HP products, refer to the hp StorageWorks SNMP reference guide for director 2/64, edge switch 2/16, and edge switch 2/32.
  • Page 19: Multi-Switch Fabrics

    All manuals and user guides at all-guides.com Introduction Zones are grouped into zone sets. A zone set is a group of zones that is enabled (activated) or disabled across all switches in a multi-switch fabric. Only one zone set can be enabled at one time. Multi-Switch Fabrics A Fibre Channel topology that consists of one or more interconnected switches or switch elements is called a fabric.
  • Page 20: Field Replaceable Units

    Introduction checking is done for pre-existing conditions and no prompts display to guide users through tasks. Refer to hp StorageWorks CLI reference guide for edge switches and directors. This manual provides details on the Product Manager application for the Edge Switch 2/32 only.
  • Page 21: Sfp Transceivers

    All manuals and user guides at all-guides.com Introduction Cooling fan (4) Power switches on power supplies Power supply (2) Figure 1–3: Edge Switch 2/32 (Rear View) SFP Transceivers A single-mode or multi-mode fiber-optic cable attaches to a port through a pluggable small form factor (SFP) transceiver.
  • Page 22: Connectors And Indicators

    All manuals and user guides at all-guides.com Introduction Each power supply has a separate CTP connection to allow for independent AC power sources. The power supplies are input-rated at 100 to 230 volts alternating current (VAC). Power supply requirements are listed in Appendix Connectors and Indicators Connectors and indicators include the:...
  • Page 23: Power And System Error Leds

    All manuals and user guides at all-guides.com Introduction Power and System Error LEDs The PWR LED, as shown in Figure 1–2 illuminates when the switch is connected to facility AC power and powered on. If the LED extinguishes, a facility power source, power cord, or power distribution failure is indicated.
  • Page 24: Hafm Server Description

    Switches. Figure 1–4: HAFM server The server is mounted in a slide-out drawer in the HP-supplied equipment rack. The HAFM server or Ethernet access to the Embedded Web Server (EWS) interface is required to install, configure, and manage the Edge Switch 2/32.
  • Page 25: Ethernet Hub

    Ethernet adapter card. This LAN port attaches to the customer’s public intranet to allow access from remote user workstations. An optional Ethernet adapter card (not supplied by HP) can be installed in the personal computer memory card international association (PCMCIA) slot to provide a connection to a private LAN segment for dedicated director communication.
  • Page 26 All manuals and user guides at all-guides.com Introduction 1–12 edge switch 2/32 installation guide...
  • Page 27: Installing And Configuring The Edge Switch

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 This chapter describes tasks to install, configure, and verify operation of the edge switch 2/32. The switch can be installed on a table or desk top, or mounted in any standard equipment rack.
  • Page 28 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Table 2–1: Installation Task Summary (Continued) Task Number and Description Required or Optional Page Task 6: Configure the Switch to the Required if Task 5: HAFM Server 2–13 HAFM Application (Optional)
  • Page 29: Installation Options

    Fabric and device connectivity are evaluated, and the related planning worksheet is complete. Refer to the hp StorageWorks product in a SAN environment: planning guide for director 2/64, edge switch 2/16, and edge switch 2/32.
  • Page 30: Task 2: Unpack, Inspect, And Install The Switch

    2. Unpack the shipping containers and inspect each item for damage. Save all shipping and packing materials. Ensure that all items on the enclosed shipping list are in each container. 3. If any items are damaged or missing, customers should contact a HP authorized service provider or reseller. Desktop Installation To install and configure the switch on a desktop: 1.
  • Page 31: Rack-Mount Installation

    8. After successful POST completion, the green power (PWR) LED remains O all other front panel LEDs turn O 9. If a POST error or other malfunction occurs, refer to the hp StorageWorks edge switch 2/32 service manual to isolate the problem.
  • Page 32: Task 3: Configure Network Information

    NOTE: If you have enabled additional port function with the HP Flexport Feature since the switch shipped from the factory, resetting the configuration will return this feature to the factory default of only 16 ports enabled.
  • Page 33 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Verify the type of LAN installation with the customer’s network administrator. If one switch is installed on a dedicated LAN, network addresses do not require change. If multiple switches are installed or a public LAN segment is used, network addresses must be changed to conform to the customer’s LAN addressing scheme.
  • Page 34: Connection Description Dialog Box

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–1: Connection Description dialog box 5. Type edge switch 2-32 in the Name field and click OK. The Connect To dialog box displays, as shown in Figure 2–2.
  • Page 35 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 6. Ensure the Connect using field displays COM1 or COM2 (depending on the serial communication port connection to the switch), and click OK. The Port Settings dialog box displays, as shown in Figure 2–3.
  • Page 36 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–4: HyperTerminal window 9. At the C> prompt, type ipconfig and press Enter. The HyperTerminal window displays with configuration information listed as follows: — MAC Address —...
  • Page 37: Task 4: Lan-Connect The Switch

    Task 4: LAN-Connect the Switch Connect the switch to the customer-supplied Ethernet LAN segment or the HP-supplied Ethernet hub. To connect the desktop or rack-mounted switch to the Ethernet LAN segment: 1. Connect one end of the Ethernet patch cable (supplied with the switch) to the RJ-45 connector (labeled 10/100) on the left front of the chassis.
  • Page 38: Task 5: Hafm Server (Optional)

    If the switch is installed on a customer-supplied LAN segment, connect the cable to the LAN as directed by the customer’s network administrator. b. If the switch is installed on the HP-supplied Ethernet hub, connect the cable to any available port on the hub.
  • Page 39: Task 6: Configure The Switch To The Hafm Application

    Configuration information must be recorded to restore the HAFM server in case of hard drive failure. The Windows 2000 operating system and the HAFM and Edge Switch 2/32 Product Manager application must also be restored. Refer to the hp StorageWorks edge switch 2/32 service manual for instructions.
  • Page 40: Task 8: Verify Switch-To-Hafm Server Communication

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Task 8: Verify Switch-to-HAFM Server Communication Communication must be verified between the switch and the HAFM server (High Availability Fabric Manager and Product Manager applications). To verify switch-to-server communication: 1.
  • Page 41: Task 9: Configure Feature Key (Optional)

    If switch operation displays degraded or a switch failure is indicated (FRU alert symbols and a yellow triangle or red diamond at the alert panel), refer to the hp StorageWorks edge switch 2/32 service manual to isolate the problem. Task 9: Configure Feature Key (Optional) Perform this task to display or install operating features that are available as customer-specified options.
  • Page 42: Configure Hp Flexport Technology Feature Key

    A feature key is a case-sensitive alphanumeric string with dashes every four characters. Configure HP Flexport Technology Feature Key This feature key enables additional port function. The factory default settings enable 16 of the 32 ports, and this feature key enables additional ports. Until this feature is enabled the additional ports will display as Not Installed in the Port Operational State window of the Hardware View and Port List View pages.
  • Page 43: Configure Feature Key Dialog Box

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–9: Configure Feature Key dialog box 3. Click New. The New Feature Key dialog box displays, as shown in Figure 2–10. Figure 2–10: New Feature Key dialog box 4.
  • Page 44: Configure Fms Feature Key

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Configure FMS Feature Key Perform this procedure to configure the FMS feature key. This feature key enables host control of the switch from an IBM System/390 or zSeries 900 Parallel Enterprise server attached to a switch port.
  • Page 45: Task 10: Configure Osms Or Ficon Management Server (Optional)

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–14: Activate FMS feature key Task 10: Configure OSMS or FICON Management Server (Optional) Perform this task to configure the open systems management server or FICON management server.
  • Page 46: Configure Fms

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 2. Allow or prohibit host (OSI server) control by selecting Host Control Prohibited. If a check mark displays, host control is prohibited. 3. Click Activate to enable a change and allow or prohibit open systems host control.
  • Page 47: Task 11: Set Switch Date And Time

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 • Active = Saved—when this option is enabled, the active configuration of logical port addresses is used when the IPL configuration file is updated. If a check mark displays, the Active = Saved option is enabled.
  • Page 48: Set Date And Time Manually

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–17: Configure Date and Time dialog box Set Date and Time Manually To set the switch date and time manually: 1. At the Configure Date and Time dialog box, click Periodic Date/Time Synchronization to deselect the option (no check mark in the box).
  • Page 49: Periodically Synchronize Date And Time

    Applications Selectively perform the following configuration tasks for the Edge Switch 2/32 Product Manager application according to the customer’s installation requirements. For additional information, refer to the hp StorageWorks edge switch 2/32 product manager user guide. • Identify the switch to the HAFM application.
  • Page 50: Configure Switch Identification

    If the switch is installed on a public LAN, the name should reflect the switch’s Ethernet network DNS host name. For example, if the DNS host name is hpes232.hp.com, enter hpes232. b. Click Set Name as Nickname and add a check mark if you want to use the name in the name field as the nickname for the switch’s WWN.
  • Page 51: Configuring The Switch

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 c. Type a switch description of 255 alphanumeric characters or less in the Description field. d. Type the switch’s physical location (255 alphanumeric characters or less) in the Location field.
  • Page 52: Switch Parameters

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–20: Configure Switch Parameters dialog box Ordinarily, you do not need to change values in this dialog box from their defaults. The only exception is the Preferred Domain ID. Change this value if the switch will participate in a multiswitch fabric.
  • Page 53 ID, the E_Ports segment, causing the fabric to segment. For more information on domain ID, refer to the section on domain ID assignment for multiswitch fabrics in the HP StorageWorks Products in a SAN Environment — Planning Manual for details. Insistent This option is not supported unless the SANtegrity feature is installed.
  • Page 54 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Enabling the rerouting delay ensures that frames are delivered in order through the fabric to their destination. If there is a change to the fabric topology that creates a new path (for example, a new switch is added to the fabric), frames may be routed over this new path if its hop count is less than a previous path with a minimum hop count.
  • Page 55: Configure Fabric Operating Parameters

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 • Use Open Systems mode for all other (non-FICON) Fibre Channel environments. Configure Fabric Operating Parameters Use procedures in this section to set parameters on the switch for fabric operation through the Configure Fabric Parameters dialog box.
  • Page 56: Fabric Parameters

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–21: Configure Fabric Parameters dialog box NOTE: Ordinarily, you do not need to change values in this dialog box from their defaults. The only exception is the Preferred Domain ID. Change this value if the switch will participate in a multiswitch fabric.
  • Page 57 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 R_A_TOV Configure resource allocation time-out value (R_A_TOV) in tenth-of-a-second increments. This variable works with the error detect time-out value (E_D_TOV) variable to control the switch’s behavior when an error condition occurs. Resources are allocated to a circuit when errors are detected and are not released for reuse until the time set by the R_A_TOV value expires.
  • Page 58: Configure Ports (Open Systems Mode)

    Interop Mode Select the following option: • Open Fabric 1.0. Select this mode if the fabric contains HP directors and switches, as well as other open-fabric compliant switches. Select this mode for managing heterogeneous fabrics. Configure Ports (Open Systems Mode)
  • Page 59 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 b. Click Blocked check box to block or unblock a port. A check mark in the box indicates the port is blocked. Blocking the port prevents the attached device from communicating with the switch.
  • Page 60: Configure Ports (S/390 Mode)

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 A right-click in the Speed column allows you to choose from a menu to set all ports to 1 Gb/sec, 2 Gb/sec, or Navigate. g. Port Binding—Click this check box to display a check mark and enable WWN binding for the port.
  • Page 61 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–23: Configure Ports dialog box (S/390 mode) a. Click 10-100 km to enable extended distance buffering for a port. A check mark in the box indicates extended distance operation up to 100 kilometers (through repeaters) is enabled.
  • Page 62: Configure Port Addresses (S/390 Mode)

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 e. Bound WWN—Enter a World Wide Name (WWN) in the proper format (xx.xx.xx.xx.xx.xx.xx.xx) or a nickname configured through the Product Manager application. The device with this WWN or nickname will have exclusive attachment to the port if WWN Binding is enabled.
  • Page 63 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–24: Configure Addresses—Active dialog box a. Select a blank Name field and type a descriptive port name of 24 or fewer alphanumeric characters. Use a name that reflects the device connected to the port.
  • Page 64 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 • Prohibit or allow connections for an entire row (row 0C is prohibited in the Configure Addresses—Active dialog box example), • Prohibit or allow connections for all switch ports, •...
  • Page 65: Configure Snmp Trap Message Recipients

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Configure SNMP Trap Message Recipients Perform this procedure to configure community names, write authorizations, and network addresses and for up to 12 SNMP trap message recipients. A trap recipient is a management workstation that receives notification (through SNMP) if a switch event occurs.
  • Page 66: Configure And Enable E-Mail Notification

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 2. To enable transmission of trap messages to configured SNMP management workstations, click Enable Authorization Traps. A check mark displays in the box when transmission is enabled, as shown in Figure 2–27.
  • Page 67 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–28: Configure E-Mail dialog box a. Type the IP address or DNS host name of the SMTP server in the SMTP server field. Use 64 alphanumeric characters or less. It is recommended the IP address be used.
  • Page 68: Configure And Enable Call-Home Features

    There are two call-home features available, and only one is installed when the HAFM application is installed on the HAFM server. To learn more about configuring Call-Home features, refer to the hp StorageWorks HAFM server installation guide. Configure Threshold Alerts A threshold alert notifies users when the transmit (Tx) or receive (Rx) throughput reaches specified values for specific switch ports or port types, (E_Ports or F_Ports).
  • Page 69: Procedures

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Procedures Use the following procedures to create a new threshold alert, or to modify, activate, deactivate, or delete an alert. Create New Alert 1. At the Hardware View for the selected switch, choose Configure > Threshold Alerts.
  • Page 70 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 2. Click New. The New Threshold Alert dialog box displays, as shown in Figure 2–30. Figure 2–30: New Threshold Alerts dialog box—first screen 3. Enter a name from one to 64 characters in length. All characters in the ISO Latin-1 character set, excluding control characters, are allowed.
  • Page 71 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 5. Click Next. A new screen displays with additional parameters. The name configured for the alert displays at the top of the screen. Click Previous to return to the previous screen, as shown in Figure 2–31.
  • Page 72 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 9. Click Next. A new screen displays for selecting ports for the alerts, as shown in Figure 2–32. Figure 2–32: New Threshold Alerts dialog box—third screen 10.
  • Page 73 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 11. Click Next. A final screen displays to provide a summary of your alert configuration. To make any changes, backwards and forwards through the configuration screens by selecting Previous and Next, as shown in Figure 2–33.
  • Page 74: Modify An Alert

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–34: Configure Threshold Alerts dialog box—alerts activated Modify an Alert Use the following steps to modify an existing threshold alert configuration. 1. Choose Configure > Threshold Alerts. The Configure Threshold Alerts dialog box displays.
  • Page 75: Activate Or Deactivate Alerts

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 6. Click Next when you are done. A Modify Threshold screen displays where you can change the % utilization, cumulative minutes for the threshold to occur before notification, and the time interval for measuring throughput and for alert notification.
  • Page 76: Task 13: Test Remote Notification (Optional)

    Because the features are configured at the HAFM application, call-home and e-mail notification are enabled for multiple switches or HP managed products. To test remote notification: 1. Close the Hardware View page for the switch and return to the Product View page by closing the window.
  • Page 77: Task 14: Back Up Hafm Configuration Data

    It is important to back up the HAFM configuration data. This data is used to restore the HAFM server operating environment in case of hard drive failure. Refer to the hp StorageWorks HAFM server installation guide for instructions on backing up the HAFM configuration data.
  • Page 78 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 3. At the browser, enter the IP address of the switch as the internet uniform resource locator (URL). Use the default IP address of 10.1.1.10, the factory preset of 10.1.1.10, or the IP address configured while performing “Task 3: Configure Network...
  • Page 79 All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 4. Type the default user name and password. NOTE: The default user name is Administrator and the default password is password. The user name and password are case-sensitive. 5.
  • Page 80: Configure Switch Ports

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Configure Switch Ports Perform the procedure in this section to configure names and operating characteristics for the switch ports. To configure one or more ports: 1. At the View window, click Configure at the left side of the window. The Configure window opens with the Ports tab displayed.
  • Page 81: Configure Switch Identification

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 c. Choose the check box in the 10-100 km column to enable extended distance buffering for a port (default is disabled). A check mark in the box indicates extended distance operation up to 100 kilometers (through repeaters) is enabled.
  • Page 82: Switch Page-Identification Tab

    If the switch is installed on a public LAN, the name should reflect the switch’s Ethernet network DNS host name. For example, if the DNS host name is hpes232.hp.com, then enter hpes232. b. Type a switch description of 255 alphanumeric characters or less in the Description field.
  • Page 83: Configure Date And Time

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Configure Date and Time Perform this procedure to configure the effective date and time for the switch. To set the date and time: 1. At the Configure window, click the Switch tab, then select Date/Time tab. The Switch page displays with Date/Time tab selected (highlighted red), as shown in Figure 2–41.
  • Page 84: Configure Switch And Fabric Parameters

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Configure Switch and Fabric Parameters Perform this procedure to configure the following switch and fabric operating parameters: Buffer-to-Buffer Credit (BB_Credit), Error Detect Time Out Value (E_D_TOV), and Resource Allocation Time Out Value (R_A_TOV), preferred domain ID and switch priority.
  • Page 85: Switch Page-Parameters Tab

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–42: Switch page—Parameters tab a. At the Preferred Domain ID field, type a value between 1 and 31 (default is 1). The domain ID uniquely identifies each switch in a fabric. All fabric-attached switches must have unique domain IDs.
  • Page 86: Set Fabric Parameters

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 c. Click the Rerouting Delay check box to enable or disable the option. If a check mark displays, the option is enabled. If rerouting delay is enabled, traffic is delayed through a fabric by the specified E_D_TOV time.
  • Page 87: Switch Page-Fabric Parameters Tab

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–43: Switch page—Fabric Parameters tab a. At the BB_Credit field, type a value between 1 an 60 buffers. The default is 16. Use a value of 60 buffers only for extended distance port operation. b.
  • Page 88: Configure Network Information

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 — HP Fabric 1.0. Default. Select this mode if the fabric contains only HP switches and switches that are operating in HP Fabric 1.0 mode. — Open Fabric 1.0. Select this mode if the fabric contains HP directors and switches, as well as other open-fabric compliant switches.
  • Page 89: Switch Page-Network Tab

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–44: Switch page—Network tab a. At the IP Address field, type the new value as specified by the customer’s network administrator (default is 10.1.1.10, factory preset is 10.1.1.10). b.
  • Page 90: Network Configuration Changes Activated

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 3. Click Activate to save the information. The following message box displays, as shown in Figure 2–45. Figure 2–45: Network configuration changes activated 4. Update the address resolution protocol (ARP) table for the browser PC. a.
  • Page 91: Configure Snmp Trap Message Recipients

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 7. Type the default user name and password. NOTE: The default user name is Administrator and the default password is password. The user name and password are case-sensitive. 8.
  • Page 92: Management Page-Snmp Tab

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 Figure 2–46: Management page—SNMP tab a. For each trap recipient to be configured, type a community name of 32 alphanumeric characters or less in the associated Community Name field. The community name is incorporated in SNMP trap messages to ensure against unauthorized viewing or use.
  • Page 93: Configure User Rights

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 3. Click Activate to save the information. The message Your changes to the SNMP configuration have been successfully activated displays. Configure User Rights Perform this procedure to configure the administrator-level and operator-level passwords used to access the Embedded Web Server interface through the Username and Password Required dialog box.
  • Page 94: User Rights Page

    All manuals and user guides at all-guides.com Installing and Configuring the Edge Switch 2/32 c. Type the administrator password again in the Confirm New Password field, as shown in Figure 2–47. Figure 2–47: User Rights page 3. For the Operator set of data fields: a.
  • Page 95: Task 16: Cable Fibre Channel Ports

    Task 17: Connect Switch to a Fabric (Optional) To provide Fibre Channel connectivity between public devices and fabric-attached devices, connect the switch to an expansion port (E_Port) of an HP director or switch. The switch port to switch port connection is called an interswitch link (ISL). To fabric-attach the switch and create an ISL: 1.
  • Page 96: Port Properties Dialog Box

    Ensure the Operational State field displays Online and the Reason field displays N/A or is blank. If an ISL segmentation or other problem is indicated, refer to the hp StorageWorks edge switch 2/32 service manual to isolate the problem. If no problems are indicated, installation tasks are complete.
  • Page 97: Task 18: Unpack, Inspect, And Install The Ethernet Hub (Optional)

    HAFM server, and one hub port is required to connect each switch. A combination of up to 48 HP products can be configured and managed by a single HAFM server, therefore multiple hubs may be required to provide sufficient port connections. These hubs must be connected in accordance with the hub manufacturer’s specifications.
  • Page 98 All manuals and user guides at all-guides.com...
  • Page 99: Flexport Upgrade Instructions

    Each port expansion kit includes eight optical transceivers, upgrade instructions, and a entitlement certificate containing transaction code for obtaining a software licence key (feature key) through an HP website. The feature key can be enabled in the switch using one of the following methods: •...
  • Page 100: Upgrading To 24 Ports

    All manuals and user guides at all-guides.com Flexport Upgrade Instructions Upgrading to 24 Ports 3–1, 3). Ports 0 through 15 should already be populated (see Figure 3–1, 2) as 1. Insert 8 new optical transceivers into ports 16 through 23 (see Figure follows: a.
  • Page 101: Upgrading To 32 Ports

    EWS to configure the feature key, refer to the online help in the EWS. If you are using CLI to configure the feature key, refer to the hp StorageWorks CLI reference guide for director 2/64, edge switch 2/16, and edge switch 2/32.
  • Page 102 All manuals and user guides at all-guides.com Flexport Upgrade Instructions 2. Choose Features from the Configure menu on the menu bar. The Configure Feature Key dialog box displays, as shown in Figure 3–2. Figure 3–2: Configure Feature Key dialog box 3.
  • Page 103 7. When you are finished configuring the switch, you can back up the configuration data. For more information, refer to the hp StorageWorks edge switch 2/32 product manager user guide. NOTE: Be sure to keep the feature entitlement certificate in a secure place.
  • Page 104 All manuals and user guides at all-guides.com...
  • Page 105: Regulatory Compliance Id Numbers

    Regulatory Model Number for this product is: RSVLB-0214 The HP StorageWorks Director 2/140 Regulatory Model Number can be found on the product label, along with the required approval markings and information. When requesting certification information for this product, always refer to this Regulatory Model Number.
  • Page 106: Federal Communications Commission Notice

    All manuals and user guides at all-guides.com Regulatory Compliance Notices Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules.
  • Page 107: Declaration Of Conformity For Products Marked With Fcc Logo-United States Only

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions regarding your product, refer to http://thenew.hp.com. For questions regarding this FCC declaration, contact: Hewlett-Packard Company Product Regulations Manager 3000 Hanover St.
  • Page 108: Iec Emc Statement (Worldwide

    All manuals and user guides at all-guides.com Regulatory Compliance Notices IEC EMC Statement (Worldwide) This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. Spécification ATI Classe A (France) DECLARATION D'INSTALLATION ET DE MISE EN EXPLOITATION d'un matériel de traitement de l'information (ATI), classé...
  • Page 109: Japanese Notice

    All manuals and user guides at all-guides.com Regulatory Compliance Notices • EN55024 1998 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11)-Electromagnetic Immunity • EN60950 (IEC60950)-Product Safety • Power Quality: (IEC610000-3-2)-Harmonics and (IEC61000-3-3)-Voltage Fluctuations and Flicker • Also approved under UL 1950, 3rd Edition/CSA C22.2 No. 950-95, Safety of Information Technology Equipment Japanese Notice Taiwanese Notice...
  • Page 110: Harmonics Conformance (Japan

    • Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. • Allow only HP authorized service technicians to repair the laser device. Laser Safety (Finland) LASERTURVALLISUUS LUOKAN 1 LASERLAITE KLASS 1 LASER APPARAT Fibre Channel -kytkinlaitteessa on 16 optista liitäntäporttia, joissa on laserdiodin...
  • Page 111: Certification And Classification Information

    All manuals and user guides at all-guides.com Regulatory Compliance Notices Laitteen käyttäminen muulla kuin käyttöohjeessa mainitulla tavalla saattaa altistaa käyttäjän turvallisuusluokan 1 ylittävälle näkymättömälle lasersäteilylle. VARNING ! Om apparaten används på annat sätt än i bruksanvisning specificerats, kan användaren utsättas för osynlig laserstrålning, som överskrider gränsen för laserklass 1. Fibre Channel -kytkinlaitteessa ei ole käyttäjän tehtäväksi tarkoitettuja huolto- tai säätötoimenpiteitä.
  • Page 112 All manuals and user guides at all-guides.com The OLM includes the following certifications: • UL Recognized Component (USA) • CSA Certified Component (Canada) • TUV Certified Component (European Union) • CB Certificate (Worldwide) The following figure shows the Class 1 information label that appears on the metal cover of the OLM housing.
  • Page 113: Declaration Of Conformity

    All manuals and user guides at all-guides.com Regulatory Compliance Notices Declaration of Conformity The Declaration of Conformity is shown on the next page. edge switch 2/32 installation guide A–9...
  • Page 114 All manuals and user guides at all-guides.com...
  • Page 115: Factory Defaults

    All manuals and user guides at all-guides.com Technical Specifications This appendix contains the following information: • Factory Defaults, page B–1 • Physical Dimensions, page B–3 • Environmental Specifications, page B–4 • Power Requirements, page B–4 • Operating Tolerances, page B–4 •...
  • Page 116: Switch Factory-Default Values For Reset

    All manuals and user guides at all-guides.com Technical Specifications Table B–2: Switch Factory-Default Values for Reset Configuration Option Configuration Description Default Identification Switch Name NULL string Switch Description “Fibre Channel Switch” Switch Contact “End User Contact (please configure)” Switch Location “End User Contact (please configure)”...
  • Page 117: Physical Dimensions

    All manuals and user guides at all-guides.com Technical Specifications Table B–2: Switch Factory-Default Values for Reset Configuration Option (Continued) Configuration Description Default SNMP SNMP Communities “public” — 5 NULL strings SNMP Write Authorizations Read only per community Trap Recipient IP Addressees 0 for each UDP Port SNMP Authorization Trap State...
  • Page 118: Environmental Specifications

    All manuals and user guides at all-guides.com Environmental Specifications Figure B–4 lists environmental ranges for shipping, storing, and operating the hp StorageWorks edge switch 2/32. Table B–4: Environmental Specifications Specification Shipping Storage Operating Weight 17.2 kg (38 lb) 15.4 kg (34 lb) 15.4 kg (34 lb)
  • Page 119 All manuals and user guides at all-guides.com Technical Specifications Table B–6: Operating Tolerances (Continued) Specification Value Shock and vibration 60 Gs for 10 milliseconds without nonrecoverable errors tolerance Acoustical noise 6.6 Bels Inclination 10° maximum Laser Information Three configurations of cards with fixed optics will be provided for each of the connector types: four extended long-wave ports, four long-wave ports, and four short-wave ports.
  • Page 120 All manuals and user guides at all-guides.com...
  • Page 121 All manuals and user guides at all-guides.com Glossary This glossary defines terms used in this guide or in other guides in this series, and is not a comprehensive glossary of computer terms. The following cross-references are used in this glossary: Contrast with.
  • Page 122 All manuals and user guides at all-guides.com Glossary backplane The backplane provides 48 VDC power distribution and connections for all logic cards. backup FRU When an active FRU fails, an identical backup FRU takes over operation automatically (failover) to maintain director and Fibre Channel link operation. beaconing Use of light-emitting diodes on ports, port cards, field-replaceable units, and directors to aid in the fault-isolation process;...
  • Page 123 All manuals and user guides at all-guides.com Glossary call-home Product feature which enables the HAFM server to automatically contact a support center and report system problems. The support center server accepts calls from the HAFM server, logs reported events, and can notify one or more support center representatives. channel Point-to-point link that transports data from one point to the other.
  • Page 124 All manuals and user guides at all-guides.com Glossary configuration data Configuration data includes: identification data, port configuration data, operating parameters, SNMP configuration, and zoning configuration. A configuration backup file is required to restore configuration data if the CTP2 card in a non-redundant director is removed and replaced.
  • Page 125 All manuals and user guides at all-guides.com Glossary default Pertaining to an attribute, value, or option that is assumed when none is explicitly specified. default zone Contains all attached devices that are not members of a separate zone. destination address Address identifier that indicates the targeted destination of a data frame.
  • Page 126 All manuals and user guides at all-guides.com Glossary E_D_TOV See error-detect time-out value. Embedded Web Server Administrators or operators with a browser-capable PC and an Internet connection can monitor and manage the director through an Embedded Web Server interface. The interface provides a GUI similar to the Product Manager application, and supports director configuration, statistics monitoring, and basic operation.
  • Page 127 All manuals and user guides at all-guides.com Glossary fabric element Any active director or node in a switched fabric. fabric port Physical interface within the fabric that connects to an N_Port through a point-to-point full duplex connection. failover Automatic and non-disruptive transition of functions from an active FRU that has failed to a backup FRU.
  • Page 128 All manuals and user guides at all-guides.com Glossary See fiber port module card. F_Port See fabric port. See field-replaceable unit. gateway A multi-homed host used to route network traffic from one network to another, and to pass network traffic from one protocol to another. gateway address A unique string of numbers (in the format xxx.xxx.xxx.xxx) that identifies a gateway on the network.
  • Page 129 All manuals and user guides at all-guides.com Glossary homogeneous fabric A fabric consisting of only HP products. hop count The number of hops a unit of information traverses in a fabric. host bus adapter Logic card that provides a link between the server and storage subsystem, and that integrates the operating systems and I/O protocols to ensure interoperability.
  • Page 130 All manuals and user guides at all-guides.com Glossary interswitch link Also known as ISL. Physical E_Port connection between two directors in a fabric. I/O configuration See input/output configuration. IOCDS A data set that contains an I/O configuration definition built by the IOCP. IOCP See input/output configuration program.
  • Page 131 All manuals and user guides at all-guides.com Glossary logical unit number Also known as LUN. In Fibre Channel addressing, a logical unit number is a number assigned to a storage device which, in combination with the storage device’s node port’s world wide name, represents a unique identifier for a logical device on a storage area network.
  • Page 132 All manuals and user guides at all-guides.com Glossary multi-switch fabric Fibre Channel fabric created by linking more than one director or fabric switching device within a fabric. name server Program that translates names from one form into another. Domain name servers (DNS) translate domain names into IP addresses.
  • Page 133 All manuals and user guides at all-guides.com Glossary Offline—when the director is set offline, all ports are set offline. The director transmits the offline sequence (OLS) to attached devices, and the devices cannot log in to the director. operating state (port) Valid states include Online, Offline, Testing, Beaconing, Invalid Attachment, Link Incident, No Light, Not Operational, Port Failure, Segmented E_Port.
  • Page 134 All manuals and user guides at all-guides.com Glossary persistent binding A form of server-level access control that uses configuration information to bind a server to a specific Fibre Channel storage volume (or logical device) using a unit number. port Receptacle on a device to which a cable leading to another device can be attached. port card Field-replaceable hardware component that provides the port connections for fiber cables and performs specific device-dependent logic functions.
  • Page 135 All manuals and user guides at all-guides.com Glossary remote access link Connection to a device or program on a computer network via a (geographically) remote workstation. remote notification A process by which a system is able to inform remote users and/or workstations of certain classes of events that occur on the system.
  • Page 136 All manuals and user guides at all-guides.com Glossary SNMP community Also known as SNMP community string. SNMP community is a cluster of managed products (in SNMP terminology, hosts) to which the server or managed product running the SNMP agent belongs. SNMP community name The name assigned to a given SNMP community.
  • Page 137 All manuals and user guides at all-guides.com Glossary unblocked port Devices attached to an unblocked port can login to the director and communicate with devices attached to any other unblocked port assuming that this is supported by the current zoning configuration.
  • Page 138 All manuals and user guides at all-guides.com Glossary zone member Specification of a device to be included in a zone. A zone member can be identified by the port number of the director to which it is attached or by its world wide name. In multi-switch fabrics, identification of end-devices/nodes by world wide name is preferable.
  • Page 139 All manuals and user guides at all-guides.com Index 10/100 Mbps LAN connectors 1–11 Configure Ports (Open Systems Mode) 2–32 Configure Ports (S/390 Mode) 2–34 Configure SNMP Trap Message Recipients 2–65 active zone set state, default value B–3 configure switch parameters dialog box 2–25 additional port function configuring configuring 2–16...
  • Page 140 All manuals and user guides at all-guides.com Index domain RSCNs 2–28 fabric segmentation e_d_tov 2–31 preferred domain ID 2–27 E_D_TOV fans 1–7 default value B–2 LEDs 1–9 e_d_tov 2–31 fabric segmentation 2–31 class A compliance notice A–2 less than r_a_tov 2–31 class B compliance notice A–2 multiswitch fabrics 2–31 FCC compliance statement, cables A–3...
  • Page 141 All manuals and user guides at all-guides.com Index Installation Options 2–3 FRU status 1–9 Installation Task Summary (table) 2–1 port SFPs 1–9 installation tasks power supply 1–9 backing-up configuration data 2–51 PWR LED 1–9 cabling Fibre Channel ports 2–69 LIN alerts, default values B–2 configuring logs, introduction 1–3 network addresses 2–6...
  • Page 142 All manuals and user guides at all-guides.com Index port binding 2–35 SNMP port blocked states, default value B–2 configuring trap message recipients, EWS port, cabling 2–69 2–65 ports configuring trap recipients, product manager binding 2–35 2–39 default values B–2 default values B–3 UDP, default value B–3 introduction 1–4 power supplies 1–7...
  • Page 143 All manuals and user guides at all-guides.com Index operating mode 2–28 Task 6, HAFM server (Optional) 2–12 preferred domain ID 2–27 Task 7, Configure the Switch to the HAFM rerouting delay 2–27 Application 2–13 switch priority 2–31 Task 8, Record HAFM Server Restore related number codes 2–32 Information 2–13 switch priority setting 2–32...
  • Page 144 All manuals and user guides at all-guides.com...

This manual is also suitable for:

Aa-rstzb-te/958-000290-000

Table of Contents