Installing Core Switch 2/64 FRUs
4. Notify the switch of a hot swap request by pushing the yellow tab on each
Note:
uninstalling the card.
5. Open both ejectors all the way, and slide the CP card out of the chassis.
6. Install the new CP card or filler panel in the slot, as follows (see
140
ejector in, and pushing the black handles slightly open until you hear a click.
Wait for the Status LED to turn off.
Wait for the Status LED to turn off in response to the hot-swap request before
a. Orient the CP card or filler panel so that the ejectors are at the front of the
chassis and the metal pan is on the left.
b. Align the flat metal side of the CP card (see
inside the upper and lower rail guides in the slot, and slide the CP card or
filler panel into the slot until it is firmly seated.
c. Close the ejectors by pressing in the black handles toward the CP card or
filler panel, until the ejectors lock. The levering action of the ejectors seat
the CP card or filler panel in the chassis.
Figure
34) or filler panel
Core Switch 2/64 V4.1 Installation Guide
Figure
34).