Operating the Core Switch 2/64
psShow
This command displays the current status of the power supplies, as shown in the
following example.
fanShow
This command displays status and RPM of the blower assemblies, as shown in the
following example.
errShow
This command shows the switch error log that lists the status of marginal/failed
components. The following example shows that the Switch 0 blower assembly has
failed.
120
sw0_155:admin> psShow
power supply #1 is OK
power supply #2 is OK
power supply #3 is OK
power supply #4 is OK
sw0_155:admin> fanshow
Fan #1 is OK, speed is 2576 RPM
Fan #2 is OK, speed is 2481 RPM
Fan #3 is OK, speed is 2481 RPM _
sw0_155:admin> errshow
Error 15
--------
0x2e3 (fabos): Dec 29 15:57:34
Switch: 0, Error FW-BELOW1, 3, envFan001 (Env Fan 1) is below
low boundary. current value : 0 RPM. (faulty)
Core Switch 2/64 V4.1 Installation Guide