Input/output setting mode
Serial
Function
No.
When the down counter count value reaches [0], the count down complete output
53
CDE
signal (CDE) will turn ON.
When the sewing machine is stopped due to thread breakage detection, the
54
DTS
stopped due to needle thread breakage detection output signal (DTS) will turn ON.
Use prohibited.
55
--1
The sewing machine rotating output signal (DRT) will turn ON while the sewing
56
DRT
machine is rotating.
The DOWN position output signal (DN) will turn ON when the DOWN position signal
57
DN
is input from the detector.
This is the buzzer output signal for notifying that a sewing machine error or
58
CB
message has occurred.
The UP position output signal (UP) will turn ON when the UP position signal is input
59
UP
from the detector.
This is the power ON output signal.
60
PWR
Specifications
[15]-9