Mitsubishi PLK-E Series Technical Manual page 196

Electronic pattern sewing machine
Table of Contents

Advertisement

Input/output setting mode
63
DAD
64
DDC
(4) Output signal setting table
Serial
Function
No.
1...16
OT0...OTF
17...24 FN1...FN8
25...32 OF1...OF8
33
NO
34
T
35
L
36
W
37
PF
38
AFL
39
AFH
40
AFE
41
DHP
42
D2H
43
RED
44
DSW
45
SP
46
TSE
47
END
48
DCS
49
DST
50
HPO
When the input signal (DAD) is turned ON, the down counter will increment by one.
When the input signal (DDC) is turned ON, the down counter will decrement by one.
When the input signal (IO0) that outputs to the virtual output 0 is turned ON, the
virtual output signal (OT0) will turn ON at any time.
(Same for OT1 to OTF)
When the pattern data function code 1 data (FNC1) is read in during sewing, the
function code 1 output signal (FN1) will be reversed <<ON/OFF>>
* When function code 1 data (FNC1) is read in at an odd number:
[The function code 1 output signal (FN1) will turn <<ON>>.]
* When function code 1 data (FNC1) is read in at an even number:
[The function code 1 output signal (FN1) will turn <<OFF>>.]
(Same for FN2 to FN8)
When the work holder input signal 1 (IF1) is turned ON, the work holder output
signal 1 (OF1) will turn ON. When the work holder input signal 1 (IF1) is turned ON,
the work holder output signal 1 (OF1) will turn OFF.
(Same for OF2 to OF8)
Nothing is output.
The thread trimming output signal will turn [ON/OFF].
The thread release output signal will turn [ON/OFF].
The wiper output signal will turn [ON/OFF].
The presser bar lifting output signal will turn [ON/OFF].
When the pneumatic type two stage work holder input signal (A2F) is turned ON
[first time], the pneumatic type two stage work holder low pressure output (AFL) will
turn ON. Note that this is valid when the [pneumatic type two stage work holder
setting (AF2)] in the [G] mode is set to [ON].
When the pneumatic type two stage work holder input signal (A2F) is turned ON
[second time], the pneumatic type two stage work holder high pressure output
(AFH) will turn ON. Note that this is valid when the [pneumatic type two stage work
holder setting (AF2)] in the [G] mode is set to [ON].
When the pneumatic type two stage work holder input signal (A2F) is turned ON
[second time], the pneumatic type two stage work holder excess work holder
release output (AFE) will turn ON. Note that this is valid when the [pneumatic type
two stage work holder setting (AF2)] in the [G] mode is set to [ON].
The home position output signal (DHP) will turn ON when the sewing machine is
stopped at the home position.
[Note that this will turn on at the virtual home position instead of the mechanical
home position when free home position or home position correction is executed.]
The secondary home position output signal (D2H) will turn ON when the sewing
machine is stopped at the secondary home position.
If the sewing machine can be driven (the work holder is lowered (ON)), when the
start switch is pressed, the READY output signal (RED) will turn ON.
When the sewing machine is stitching (including feed data), the during stitching
signal (DSW) will turn ON.
When the sewing machine starts to rotate after feed data the output signal (SP) will
turn ON.
The thread trimming start output signal (TSE) will turn ON when the thread trimming
operation starts.
The stitching end output signal (END) will turn ON when one stitching pattern is
completed.
When the sewing machine is halted with the HALT code data (UST, DST) during
stitching, the HALT (code) output signal (DCS) will turn ON.
The halted output signal (DST) will turn ON while the sewing machine is halted.
The during home return output signal (HPO) will turn ON while the sewing machine
is returning to the home position.
[15]-7