Mitsubishi PLK-E Series Technical Manual page 194

Electronic pattern sewing machine
Table of Contents

Advertisement

Input/output setting mode
(3) Input signal setting table
Serial
Function
No.
1
FSP
2
FSM
3
FP1
4
FM1
5
FP2
6
FM2
7
IFR
8
A2F
9...16
IF1...IF8
17...24 F1C...F8C
25
OFC
Each time the input signal (FSP) is turned ON, the work holder output [1], [2], [3],
[4], [5], [6], [7] and [8] will turn <<ON>> in sequence.
When the ["valid work holder number setting (FN)" is set to "1" for the program/
work holder mode], this input signal (FSP) will be invalid.
Each time the input signal (FSM) is turned ON, the work holder output [8], [7], [6],
[5], [4], [3], [2] and [1] will turn <<ON>> in sequence.
When the ["valid work holder number setting (FN)" is set to "1" for the program/
work holder mode], this input signal (FSM) will be invalid.
Each time the input signal (FP1) is turned ON, the work holder output [1], [2], [3]
and [4] will turn <<ON>> in sequence.
If either of the following is established, this input signal (FP1) will be invalid:
[When "number of work holder division setting (OFB)" in the program/pressure
mode is set to NO or 4]
[When the "valid work holder number for divided work holder setting (F21N)" is set to 1]
Each time the input signal (FM1) is turned ON, the work holder output [4], [3], [2]
and [1] will turn <<ON>> in sequence.
If either of the following is established, this input signal (FM1) will be invalid:
[When "number of work holder division setting (OFB)" in the program/pressure
mode is set to NO or 4]
[When the "valid work holder number for divided work holder setting (F21N)" is set to 1]
Each time the input signal (FP2) is turned ON, the work holder output [5], [6], [7]
and [8] will turn <<ON>> in sequence.
If either of the following is established, this input signal (FP2) will be invalid:
[When "number of work holder division setting (OFB)" in the program/pressure
mode is set to NO or 4]
[When the "valid work holder number for divided work holder setting (F22N)" is set to 1]
Each time the input signal (FM2) is turned ON, the work holder output [8], [7], [6]
and [5] will turn <<ON>> in sequence.
If either of the following is established, this input signal (FM2) will be invalid:
[When "number of work holder division setting (OFB)" in the program/pressure
mode is set to NO or 4]
[When the "valid work holder number for divided work holder setting (F22N)" is set to 1]
When the input signal (IFR) is ON, all (ON state) work holder outputs will turn
<<OFF>>.
Each time the input signal (A2F) is turned ON, the following operations (1), (2) and
(3) will be repeated in sequence.
Note that this is valid only when the [pneumatic type two stage work holder setting
(AF2.)] function in the program mode is set to [ON].
(1) When the input signal (A2F) is turned ON [first time], the pneumatic type two
stage work holder low pressure output (AFL) will turn <<ON>>, and the
pneumatic type two stage work holder residual pressure removal output (AFE)
will turn <<OFF>>.
(2) When the input signal (A2F) is turned ON [second time], the pneumatic type two
stage work holder low pressure output (AFL) will turn <<OFF>>, pneumatic type
two stage work holder high pressure output (AFH) will turn <<ON>>.
(3) When the input signal (A2F) is turned ON [third time], the pneumatic type two
stage work holder high pressure output (AFH) will turn <<OFF>>, and the and
the pneumatic type two stage work holder residual pressure removal output
(AFE) will turn <<ON>>.
When the input signal (IF1) turns ON, the work holder output 1 (OF1) will turn ON.
When the input signal (IF1) is turned ON again, the work holder output (OF1) will
turn OFF.
(Same for IF2 to IF8).
When the input signal (F1C) is ON, output (ON) of the work holder output 1 (OF1)
will be prohibited.
[Operation of the work holder output 1 input signal (IF1) is invalidated.]
(Same for F2C to F8C).
When the input signal (OFC) is ON, output of the work holder output 1 (OF1) to
work holder output 8 (OF8) are all prohibited.
[Operation of the work holder output 1 input signal (IF1) to work holder output 8
input signal (IF8) is invalidated.]
[15]-5