Installing Dmp-1 Dampening Material - GE TransPort PT878GC User Manual

Portable gas flowmeter
Table of Contents

Advertisement

April 2009

Installing DMP-1 Dampening Material

1. Be sure the CFG-V clamping fixture is installed on the pipe
with the transducers as described in the section Installing the
V Series Clamping Fixture and Transducers on page 3-14.
With a marker, mark scribe lines on the inside edges of the
brackets onto the pipe. These lines indicate where to apply the
material. (One 9.5-in. roll fits between the brackets.)
2. Remove the fixture and transducers.
3. Use a dry towel or rag and thoroughly dry the pipe.
4. Unroll the DMP-1 material and cut off a length equal to the
circumference. Peel the paper backing off the cut portion.
IMPORTANT:
5. Before more atmospheric condensation can occur on the
outside of the pipe, roll the DMP-1 dampening material once
around the pipe, following the scribe marks that represent the
inside edge of the fixture, as shown in Figure 3-23 below.
Figure 3-23: DMP-1 Dampening Material
6. Reinstall the fixture, and make sure the spacing is set
correctly. Loosely mount the transducers on top of the
dampening material, using the correct spacing.
3-26
Installing the Dampening Material, Transducers and Fixtures
The DMP-1 material will only adhere to the pipe
correctly if the pipe is completely dry. To adhere
properly, the material must also be at a
temperature above 50°F (10°C).
Wrapped Around Pipe