Parameters for Special Transducers (cont.)
Note: If the transducer is installed on a pipe that is at a different
temperature than the ambient temperature, the wedge
temperature is the average of the pipe temperature and
the ambient temperature.
7. Finally, the PT878GC requires the wedge sound speed.
a. From the Wedge Temp prompt, press the [
the Wedge SS prompt, and press
b. Use the numeric keys to enter the GE Sensing-supplied
wedge sound speed (in ft/sec or m/sec) and press
Pressing the [ ] key returns the meter to the Transducer tab at
the top.
To confirm the entries and return to Operate Mode, press
(OK).
To leave the window without confirming the entries and return
to Operate Mode, press
4-6
[ENTER]
[F2]
(Cancel) or the
] key to reach
.
[ENTER]
[F3]
[ESC]
key.