Fuel Supply System
Fuel Line/Quick-Connect Fittings Installation
1. Check the contact area (A) of the line (B) for dirt and
damage, and clean if necessary.
2. Insert a new retainer (A) into the connector (B) if the
retainer is damaged, or after
• replacing the fuel rail.
replacing the fuel feed line.
• replacing the fuel pump.
• replacing the fuel filter.
replacing the fuel gauge sending unit
• removing the retainer from the line.
~.
11-150
3. Before connecting a new fuel tube/quick-connect
fitting assembly (A), remove the old retainer from
the mating line.
•